NeuroLinkage: Echtzeit-Intentionsdekodierung, epidurale Rückenmarkstimulation & Sub-20ms-Motor-Loops
NeuroLinkage entwickelt ultrahochdichte kortikale Brain-Computer-Interfaces (BCIs), die Tausende simultane Nervenkanäle von intrakortikalen Mikroelektroden übertragen, On-Chip-Spike-Sorting ausführen und artikulierte Sprache sowie Robotersteuerung für tetraplegische Patienten synthetisieren.
NeuroLinkage High-Density Cortical BCI & Signal Processing Architecture
1024-channel cortical probe, on-chip spike sorting ASIC, and low-latency decoding server
Central System: Cortical BCI Processor - High-Density Spike Sorting Core
Clinical IoMT Nodes
- High-Density Intracortical Microelectrode Array
- On-Probe Neuromorphic Digitizer ASIC
- Real-Time Neural Spike Sorting Core
- Motor & Speech Intent Neural Decoder
- Assistive Communication / Exoskeleton Sink
Architectural Layers & Regulatory Standards
- Intracortical Silicon / Polymer Probes (Neuropixels Architecture / Flexible Polyimide Shanks): Recording extracellular single-unit action potentials from pyramidal neurons across cortical layers I-VI.
- Ultra-Low Power Neural Signal Digitization (Analog Front-End ASIC / 30 kHz Per Channel Sampling): Digitizing hundreds of raw electrical channels directly at the skull interface without thermal tissue heating.
- On-Edge Neural Spike Detection & Sorting (Threshold Crossing / Waveform Feature Clustering): Isolating individual neuronal action potentials from background multi-unit hash in real time.
- High-Bandwidth Intent Decoding & Synthesis (Temporal Convolutional Networks / RNN Language Models): Decoding cortical motor intent into continuous 2D/3D cursor kinematics or acoustic phoneme sequences.
Key Metrics: 1024 Channels (Simultaneous Cortical Recording) | < 0.5°C (Implantable Thermal Dissipation Rise) | 90 WPM (Decoded Speech Synthesis Rate) | < 25 ms (Brain-to-Actuator Latency)
Kortikale neuronale Verknüpfung, hochdichte Mikroelektroden-Arrays und Spike-Sorting-Neuromodulation
Autoritative technische Referenz fuer cortical neural linkage, high-density microelectrode arrays & spike sorting neuromodulation gemaess FDA 510(k), EU MDR, IEC 62304 Klasse C Software-Lebenszyklus und IoMT-Interoperabilitaet.
Core Engineering Areas
Technical Articles
Related Cluster Architecture Specifications
- HealthVigilance — Zero-Trust IoMT Architecture, SaMD Risk Engineering & Autonomous Clinical Post-Market Vigilance
- AgenticSaMD — Autonomous Agentic Software as a Medical Device, Multi-Agent Clinical Decision Support & FDA GMLP Guardrails
- AITelemonitoring — Autonomous AI Telemonitoring, Virtual Nursing Assistants & Predictive Clinical Deterioration Scoring
- BCI2IoMT — Brain-Computer Interface IoMT Gateways, Neural Decoding & Electrophysiological Streaming